• Triple Multi-Functional Air Source Heat Pump Radiant Floor Heating Cooling
  • Triple Multi-Functional Air Source Heat Pump Radiant Floor Heating Cooling
  • Triple Multi-Functional Air Source Heat Pump Radiant Floor Heating Cooling
  • Triple Multi-Functional Air Source Heat Pump Radiant Floor Heating Cooling
  • Triple Multi-Functional Air Source Heat Pump Radiant Floor Heating Cooling
  • Triple Multi-Functional Air Source Heat Pump Radiant Floor Heating Cooling

Triple Multi-Functional Air Source Heat Pump Radiant Floor Heating Cooling

Energy Efficiency Grade: One
Heat Temperature: 50-70°C
Work Environment: Common Heat Pump
Heat Source: Air-source
Heating Type: Multi-power Heat
Application: Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons, Restaurants, Home
Samples:
US$ 810/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
KCHR-15II/BP
Certification
CE, ISO9001, CCC
Rated Heating Capacity(A24/26oc)
8kw
Noise dB(a)
<50
Kw
8-220kw
Transport Package
Wooden Box Export Package
Specification
8kw
Trademark
Leomon
Origin
China
HS Code
84189910
Production Capacity
50000/PCS

Product Description

The hot water heat pump draws heat from the surrounding air, and then transfers the heat to the water tank to heat the water. Air source heat pumps can be used not only to heat hot water, but also to heat and cool houses.

The hot water heat pump can heat water to 30°C to 60°C. It consumes 70-80% less electricity than traditional electric water heaters, so the heat pump will save you a lot of electricity bills.

Function
1. Heating
2. Cooling
3. Hot water


Hot Water Heat Pumps Features:
1. Well-known brand scroll compressor
2. Stainless steel storage tank or enamel storage tank.
3. Efficient and environmentally friendly R134A or R417A refrigerant, no ozone depletion
4. Copper pipe with inner groove, higher efficiency
5. Intelligent control: with LCD display and digital remote control
6. Water temperature adjustment range: 25ºC-60ºC
7. Electronic expansion valve (EEV) is used for reliable and high-precision expansion
.Shell and tube or in-tube water heat exchanger, the maximum working water pressure is up to 3.2Mpa
8. Compact design, optional 80L / 200L / 300L
9. Low noise, will not disturb neighbors
10. Automatic sterilization to ensure water quality
11. Extremely compact structure, beautiful appearance, good detachability
OEM/ODM Service
1. Galvanized steel or 304 stainless steel cabinet is optional.
2. Grey, white, black and other color is optional.
3. Heating function, cooling function, and hot water function are optional.
4. OEM brand name is optional.
5. ODM cabinet is optional.
6. Other power supplies (110V, 60Hz) are optional.

Triple Multi-Functional Air Source Heat Pump Radiant Floor Heating Cooling
Warranty:
1. CE, CB, RoHS, Conform to EN14511-2:2011 test standard, ISO9001, ISO14001.
2. 2 year warranty


Hot Water Heat Pumps Specifications:

Triple supply parameters Cooling, heating and hot water functions
Item KCHR-8I/BP
Side wind
KCHR-13I/BP
Side wind)
KCHR-15I/BP
Side wind
KCHR-15II/BP
(Out of the wind)
Rated voltage 220V~50Hz 220V~50Hz 220V~50Hz 380V 3N~50Hz
Cooling and heating Nominal cooling
 capacity
7.8kW(2kW-9kW) 13kW(3kW-15kW) 14.5kW(4kW-16.5kW) 14.5kW(4kW-16.5kW)
Nominal cooling power
consumption
2.77KW 4.6KW 5.27KW 5.27KW
Nominal cooling(COP) 2.81 2.82 2.75 2.75
IPLV 4.11 4.13 4.02 4.02
Nominal heating capacity 8.4kW(2.5kW-9.6kW) 14kW(3.5kW-16kW) 17kW(4.3kW-18.5kW) 17kW(2.5kW-18.5kW)
Nominal heating power
consumption
2.78KW 4.5KW 5.6KW 5.6KW
Heating Nominal heating capacity 6.8KW 10.5KW 13KW 13KW
Nominal heating
power consumption
1.75KW 2.65KW 3.3KW 3.3KW
Nominal heating(COP) 3.88 3.96 3.93 3.93
Maximum operating current 20A 33A 41A 21A
Maximum power consumption 4KW 6.6KW 7.9KW 7.9KW
Rated water flow 1.34m²/h 2.24m²/h 2.5m²/h 2.5m²/h
Refrigerant/charge volume R410A/1750g R410A/4000g R410A/4000g R410A/4800g
noise ≤54dB(A) ≤56dB(A) ≤57dB(A) ≤58dB(A)
Water resistance ≤14kPa ≤15kPa ≤21kPa ≤21kPa
Maximum working pressure on low
pressure/high pressure side
4.5Mpa/0.15Mpa 4.5Mpa/0.15Mpa 4.5Mpa/0.15Mpa 4.5Mpa/0.15Mpa
Allowable working pressure on
suction/exhaust side
4.5Mpa/0.15Mpa 4.5Mpa/0.15Mpa 4.5Mpa/0.15Mpa 4.5Mpa/0.15Mpa
Anti-shock level I I I I
waterproof level IPX4 IPX4 IPX4 IPX4
Unit size (l× w × h) 1030×410×865(mm) 1030×410×1390(mm) 1030×410×1390(mm) 820×780×1700(mm)
(Cold and warm) Caliber of inlet
and outlet
DN25 DN32 DN32 DN32
(Hot water) Caliber DN20 DN25 DN25 DN25
Application area 60 100 110 110
Nominal refrigeration conditions: ambient dry bulb 35ºC, outlet temperature 7ºC. Nominal heating conditions: ambient dry bulb 7ºC, ambient wet bulb 6ºC,
outlet temperature 45ºC
Nominal hot water production conditions: ambient dry bulb 20ºC, ambient wet bulb 15ºC, initial water temperature 15ºC, end water temperature 55ºC.
About Us:
1. Over 400 patents of air source heat pumps and other HVAC products
2. Marketing and technical support for Customer
3. Fully and quick after sale service
4. Decades experience manufacturing experience
5. Leader memeber for editting heat pumps standard

  Triple Multi-Functional Air Source Heat Pump Radiant Floor Heating CoolingTriple Multi-Functional Air Source Heat Pump Radiant Floor Heating CoolingTriple Multi-Functional Air Source Heat Pump Radiant Floor Heating Cooling

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now