Energy Efficiency Grade: One
Heat Temperature: 50-70°C
Work Environment: Common Heat Pump
Heat Source: Air-source
Heating Type: Multi-power Heat
Application: Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Samples:
US$ 810/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
28kw
Certification
CE, ISO9001, CCC, RoHS
Wi-Fi
Optional
Noise Level
50dB(a)
Ambient Temp
-15°c-46°c
Function
Heating & Cooling
Voltage
220V 50Hz/60Hz
Color
White, Black, Red, etc
Refrigerant
R401A, R32, CO2, R290
Fan Motor
DC Fan Motor
Compressor
DC Inverter Compressor
Heat Exchanger
High Titanium Tube Heat Exchanger
Casing/Colour
ABS Plastic/Black Cabinet
Transport Package
Wooden Box Export Package
Specification
3kw,5kw,,7kw,9kw,10kw,14kw,15kw,16kw,20kw27kW, 41k
Trademark
Leomon Heat Pumps
Origin
China
HS Code
84189910
Production Capacity
50000/PCS

Product Description

R290 Heat Pump Water Heater COP 4.53
The compact heat pumps we have, 150L, 200L, 270L, 340L. GMO has solutions for your home or commercial project.

Our broad product range can serve one-bedroom/bathroom residences, all the way to multi-storey offices, hotels, motels, resorts, leisure facilities, retail stores. We can also tailor solutions for your specific commercial application.

R290 is a near-perfect refrigerant: negligible global warming potential (GWP), zero ozone depletion potential (ODP), degradation time in months, a permanent green alternative in the long run, Less load, lower energy consumption and higher efficiency under the same performance.

Features

1. Save electricity bills
Reduce running costs by up to 80% compared to some power storage devices.

2. Suitable for harsh water conditions
The water does not come into contact with any operating parts, only the lining of the tank.

3. Solar power without panels
Hot water from solar energy, no direct sunlight or roofing required. The heat pump produces hot water day and night.

4. Easy installation
The compact design reduces labor and installation costs.

How does this work
Solar heat pump water heaters use heat from the ambient air around the system, and reverse the cooling process to heat the water. This means no sunlight exposure is required, and more importantly, it is so efficient that it can provide reliable hot water 24 hours a day, even at temperatures as low as -10°C, without the need for booster elements. 1. The sun heats the air. Heat pumps rely on ambient air temperature rather than occasional sunlight. Using the principle of refrigeration, heat pumps can extract heat from the air without requiring direct sunlight, and can produce hot water in the presence of rain, hail or sunlight without the need for a booster element. 2. Energized air is introduced into the heat pump. Once the air is drawn into the heat pump, it passes through an evaporator containing refrigerant, which boils at a very low temperature. The boiling refrigerant is then compressed, causing its temperature to rise and even further convert it into superheated steam. 3. Energy is transferred to heating cold water. Using tank wrapping technology, this superheated steam is fed through a copper coil (condenser) wrapped around the outside of the tank to heat the water evenly and efficiently from outside to inside. 4. Cold air is exhausted. Once the heat is extracted from the air and transferred to the water, the remaining cool air is expelled from the heat pump by a fan. Once the desired water temperature is reached, the system will enter an energy-saving standby mode until it is time to start heating again. Using tank wrapping technology, this superheated steam is fed through a copper coil (condenser) wrapped around the outside of the tank to heat the water evenly and efficiently from outside to inside. 4. Cold air is exhausted. Once the heat is extracted from the air and transferred to the water, the remaining cool air is expelled from the heat pump by a fan. Once the desired water temperature is reached, the system will enter an energy-saving standby mode until it is time to start heating again. Using tank wrapping technology, this superheated steam is fed through a copper coil (condenser) wrapped around the outside of the tank to heat the water evenly and efficiently from outside to inside. 4. Cold air is exhausted. Once the heat is extracted from the air and transferred to the water, the remaining cool air is expelled from the heat pump by a fan. Once the desired water temperature is reached, the system will enter an energy-saving standby mode until it is time to start heating again.

Quality parts
1. SCI compressor for R-290 refrigerant as R-290 is a new alternative refrigerant with lower ODP and GWP than other traditional refrigerants.
2. High quality liquid line filter dryer
3. High quality expansion valve 290
4. High quality sight glass
5. 100% copper material 55m heat exchanger wraps 95% of the outer surface area of the cylinder, the fastest hot water recovery rate
6. GMO Enamel Coated Heat Pump Water Tank
7. Titanium blue liner
8. P/T safety valve,
9. Watermark Authentication
 
Model LMAD-100 LMAT-150 LMAT-200 LMAT-240 LMAT-280 LMAT-330
The refrigerant R134a
Heating KW 100 150 200 240 280 330
Input power
(rated condition)
KW 38 55 70 85 100 113
power supply  3φ-380V-50HZ
protective device Reverse phase loss protection, over current protection,
motor temperature protection, high and low voltage protection,
high and low temperature protection, water flow protection
Refrigeration circuit 1
Energy control (%) 0,50,75,100
Refrigerant charge (kg) 100 150 160 180 200 220
Finned heat exchanger Copper tube wearing hydrophilic corrugated aluminum sheet
Fan Form Axial Flow
Flow (m3/h) 60000 60000 90000 90000 120000 120000
Power (kw) 6 6 9 9 12 12
Water side maximum pressure MPa Form Shell and tube heat exchanger
Water side maximum pressure MPa 1
 Import and export pipe diameter DN65 DN80 DN100 DN100 DN125 DN125
Hot water flow 17.2 25.8 34.4 41.3 49 56.8
Water pressure drop 38 42 45 48 52 55
Running noisedB(A) 75 77 78 80 81 82
Unit length(mm) 3360 3360 5000 5000 6000 6000
Unit width(mm) 2260 2260 2230 2230 2230 2230
Unit height(mm) 2500 2500 2500 2500 2500 2500
Unit weight(kg) 4000 4300 6400 6700 8100 8500
Running weight(kg) 4500 4800 7000 7300 8700 9200
1. According to GB/T 25127.1-2010, the nominal heating standard: ambient dry bulb temperature -12°C,
ambient wet bulb temperature -14°C, hot water outlet temperature 41°C, water flow 0.172 m3 / h * kW;
2, The ambient temperature range: -25 ° C ~ 21 ° C; Tot water temperature range: 35°C ~ 70°C;
3. The unit parameters are subject to change without prior notice. The specific parameters are subject to the product nameplate;
4. KMAD-100 unit is a heating and cooling unit, GB/T 25127.1-2010 national standard nominal cooling capacity is
5.  for the upcoming product model.
 
Model LMAT-130A* LMAT-190A* LMAT-290A* LMAT-350A LMAT-350AV
The refrigerant R22
Heating KW 130 190 290 350 350
Input power
(rated condition)
KW 45 65 98 118 120
power supply  3φ-380V-50HZ
protective device Reverse phase loss protection, over current protection,
motor temperature protection, high and low voltage protection,
high and low temperature protection, water flow protection
Refrigeration circuit 1
Energy control (%) 0,50,75,100
Refrigerant charge (kg) 160 180 200 220 220
Finned heat exchanger Copper tube wearing hydrophilic corrugated aluminum sheet
Fan Form Axial Flow
Flow (m3/h) 60000 90000 120000 120000 120000
Power (kw) 6 9 12 12 12
Water side maximum pressure MPa Form Shell and tube heat exchanger
Water side maximum pressure MPa 1
 Import and export pipe diameter DN80 DN100 DN125 DN125 DN125
Hot water flow 22.4 32.7 49 60.2 60.2
Water pressure drop 45 48 52 55 55
Running noisedB(A) 80 80 82 85 85
Unit length(mm) 3500 5000 6000 6000 6000
Unit width(mm) 2230 2230 2230 2230 2230
Unit height(mm) 2500 2500 2500 2500 2500
Unit weight(kg) 4500 6200 8000 8500 8500
Running weight(kg) 5000 6700 8700 9000 9000
1. According to GB/T 25127.1-2010, the nominal heating standard: ambient dry bulb temperature -12°C,
ambient wet bulb temperature -14°C, hot water outlet temperature 41°C, water flow 0.172 m3/h*kW;
2. The ambient temperature range: -35°C ~21°C; Tot water temperature range: 35°C ~55°C;
3. The unit parameters are subject to change without prior notice. The specific parameters are subject to the product nameplate.
4.  for the upcoming product model.

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now