• CO2 Hot Water Air Source Heat Pump
  • CO2 Hot Water Air Source Heat Pump
  • CO2 Hot Water Air Source Heat Pump
  • CO2 Hot Water Air Source Heat Pump
  • CO2 Hot Water Air Source Heat Pump
  • CO2 Hot Water Air Source Heat Pump

CO2 Hot Water Air Source Heat Pump

Energy Efficiency Grade: One
Heat Temperature: 80-90°C
Work Environment: Low-temperature Heat Pump
Heat Source: Air-source
Heating Type: Multi-power Heat
Application: Villa Family, Sauna and Swimming Pool, Hotels, Factory Hospital, Student Apartments, Beauty Salons
Samples:
US$ 1000/Piece 1 Piece(Min.Order)
| Request Sample
Customization:
Diamond Member Since 2021

Suppliers with verified business licenses

Manufacturer/Factory

Basic Info.

Model NO.
SJKRS-28 II/C
Certification
CE, ISO9001, CCC, CB, UL, RoHS, SASO, CSA
Heating Capacity
6-160kw
Compressor
Dorin CO2 Compressor or Panasonic
Refrigerant
CO2 R744
Inverter Circulator
Wilo
Output Hot Water Temperature
45 to 90 ° C Max.
Operating Ambient Temperature
-35 ° C to 43 ° C
Ventilation
1 Fan
Controller
Carel
Transport Package
Export Package
Specification
1450x950x1450
Trademark
Leomon
Origin
China
HS Code
84189910
Production Capacity
50000PCS/Year

Product Description

Principle Introduction
The compressor sucks low-temperature and low-pressure gas carbon dioxide refrigerant from the evaporator, and compresses the carbon dioxide refrigerant into a high-temperature and high-pressure supercritical fluid through work. The high-temperature and high-pressure supercritical fluid enters the gas cooler to exchange heat with water, and is cooled in the gas cooler. The high-pressure fluid releases a lot of heat, and the water absorbs the heat released and the temperature continues to rise. After the high-pressure fluid is throttled and depressurized by the expansion valve, in the evaporator, the fan absorbs the heat in the surrounding air and evaporates into a low-pressure gas, which is sucked into the compressor and compressed, so that it is repeatedly circulated to produce hot water.
Features
Natural environmental protection refrigerant: ODP is 0, GWP is 1, no pollution to the environment, non-toxic, non-flammable
Excellent high temperature heating performance: the highest water output can reach above 90ºC
Excellent low temperature performance: at -20°C ambient temperature, 90°C high temperature hot water can still be produced
High efficiency: the heating performance COP can reach 4.5, and when the hot water is produced at low temperature, the COP is still above 2.0
Wide range of application: it can work normally in the ambient temperature range of -20ºC~43ºC, suitable for the production of domestic or industrial hot water
System schematic diagram
CO2 Hot Water Air Source Heat Pump
Introduction of carbon dioxide heat pump water heater              
Technical Parameters
Unit type SJKRS-28 II/C SJKRS-36II/C SJKRS-55 II/C SJKRS-73 I/C SJKRS-106 IC SJKRS-I60II /C
Specifications 7.5HP 10HP 15HP 20HP 30HP 40HP
Power supply Three-phase five-wire380V/50Hz
Heating mode Direct heat/cycle type
Standard working condition Heating capacity( kw ) 27.5 36.7 55.1 72.8 10.6.5 155.1
Input Power(kW) 6.1 8.2 13.7 16.1 23.6 34.5
COP 4.5 4.5 4.5 4.5 4.5 4.5
Hot Water flow(m³/h) 0.59 0.79 1.18 1.56 2.29 3.33
High temperature condition Heating capacity kw ) 23.9 28.5 51.5 59.5 89 13.1.5
Input Power(kW) 7.5 8.9 16.1 18.6 27.8 41.1
COP 3.2 3.2 3.2 3.2 3.2 3.2
Hot Water flow(m³/h) 0.27 0.33 0.59 0.68 1.02 1.51
Low temperature condition Heating capacity( kw ) 17.3 21.4 34.8 41.5 62.2 94.5
Input Power(kW) 6.2 7.6 12.4 14.8 22.2 33.8
COP 2.8 2.8 2.8 2.8 2.8 2.8
Hot Water flow(m³/h) 0.32 0.4 0.65 0.78 1.16 1.77
Component Information Size of water pipe joint DN20 DN25 DN32 DN40
Water heat exchanger Plate or sleeve heat exchanger
Air Heat Exchanger Aluminum Fin for copper tube
compressor type Semi-closed reciprocating
Operation Panel Color touch screen
Maximum outlet temperature(ºC) 90ºC
Refrigerants R744 (CO2 )
Design pressure(MPa) High side 15, low side 8
Dimensions (length, width and height mm) 1450x950x1450 1600x950x1500 1850x1150x1900 2050x1150x1950 2670x1410x2150 2290x2270x1980
Noise (dB) 56 59 62 67 70 70
Weight(kg) 550 660 780 860 1180 221360
SCOPE of use Feed water temperature(ºC) 5~ 40
Feed water pressure 0.05~ 0.4
Effluent temperature(ºC) 55~ 90
Maximum flow 1.2 1.5 2.4 3.2 4.9 6.5
Ambient temperature(ºC) '-20~43
Note: 1) standard working conditions: ambient temperature DB 20 ° c/WB 15 ° C, using side initial water temperature 15 ° C,
termination water temperature 55 ° c;
  2) high temperature effluent: Ambient Temperature DB 20 ° c/WB 15 ° C, using side initial water temperature 15 ° C,
termination water temperature 90 ° c;
  3) low temperature working condition: ambient temperature DB-10 °C, using side initial water temperature 9 °C,
termination water temperature 55 °c;
Usage of the ehat pumps: companies, factories, buildings, school. university, cold climate, etc
CO2 Hot Water Air Source Heat PumpCO2 Hot Water Air Source Heat PumpCO2 Hot Water Air Source Heat Pump

Send your message to this supplier

*From:
*To:
*Message:

Enter between 20 to 4,000 characters.

This is not what you are looking for? Post a Sourcing Request Now